PVP250kW & PVP260kW Inverter
Installation & Operation Manual
Connecting the Ethernet Cable to the Internet
Use the following steps to complete the connection of the Data Monitoring Module:
1. Route the Ethernet (CAT5) cable from the Internet-enabled router, at the gland plate
location on the upper right side of the inverter, using the proper conduit and hub con-
nectors. Refer to section
4.4 Conduit Entry
for instructions on how to properly use
gland plates.
2. Plug the Ethernet cable into the Ethernet port on the Comm X PCB located in the
Data Monitoring Section. Refer to the following gure.
Ethernet Port
Figure 4-18 Comm X PCB Ethernet Port Location
When the Internet connection is established, go to www.mypvpower.com to register
the inverter and begin using the monitoring tools. Contact PV Powered if additional
information is needed on how to use this online tool.
Advanced Networking and Troubleshooting
All PV Powered commercial inverters come standard with an Ethernet port that is
intended to be connected to the Internet. The PV Powered commercial inverter operates
as an Internet appliance. The inverter communicates with the PV Powered Data Center
using https (port 443). Communications is one way – the inverter only communicates
externally to the PV Powered Data Center. Typically the inverter will post 1Kb to 2Kb of
data via web service call to the data center every 15 minutes. If there is an inverter fault,
the inverter may post data more frequently for a short period of time.
Below is a list of requirements to establish inverter communications with the PV Powered
Data Center. Connectivity must be established before registration on www.mypvpower.
com is attempted.