4.8 Performance Monitoring and Networking
The inverter has an integrated Data Monitoring Module located in a dedicated Data
Monitoring section. The Data Monitoring Module enables access to the inverter
performance data in two ways. First, basic performance data can be accessed using a free
web-based monitoring service provided by PV Powered. Second, the Data Monitoring
Module can deliver data to a third party monitoring system over a Modbus RS-485
network.
Ethernet Network Connection
PV Powered offers a free basic monitoring service through the mypvpower.com website.
Internet service must be set up properly at the installation site before the inverter can be
accessed online. The Data Monitoring Module supports only hard-wired CAT5 solutions
to the inverter. It does
NOT
support wireless congurations. To access the mypvpower
data monitoring information, customers need to provide a broadband Ethernet connection
to the inverter, based on the following specications:
Provide a DHCP-enabled broadband internet connection that is always ON. This can
be cable internet, a DSL line, or equivalent.
Requires a hard-wired, Ethernet-enabled connection available at the inverter location.
Internet service should be connected using one of the following preferred methods:
Hard wire an outdoor-rated, shielded CAT5 Ethernet cable between the invert-
ers Data Monitoring Module and the DHCP-enabled Internet connection.
If multiple inverters are commissioned to a single site, you can use an Ethernet
hub located in an outdoor-rated enclosure to distribute Ethernet cables to the
inverters.
NOTE: The Data Monitoring Module does not support dial-up modem connectivity.
NOTE: Some complex networks might require a system administrator to add the
inverter to the network.
IMPORTANT: The Ethernet cable must comply with T-568B standards. This is the
only conguration supported by the Data Monitoring Module. Other wiring
congurations will not work. Refer to the following gure.
1 2 3 4 5 6 7 8
Front
Bottom
Figure 4-17 T-568B Compliant Ethernet Cable