PV Powered PVP2000 Specifications Page 11

  • Download
  • Add to my manuals
  • Print
  • Page
    / 23
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 10
PV Powered LLC 10 32-29-28-20-306
4. Connect the LINE 2/NEUTRAL wire to the terminal marked ‘line 2/neutral’ inside
the StarInverter.
5. Connect the LINE wire to the terminal marked ‘line’ inside the StarInverter.
6. Ensure all connections are wired correctly and properly torqued. Tighten the
terminal block screws to 0.5 Nm.
Figure 8: AC wiring for the line, line 2/neutral and ground wires.
2.3.c Connecting DC Wires/PV Panels
WARNING: Before proceeding with the DC wiring, completely cover the
surface of all PV-arrays with dark material to avoid the production of electrical
current.
WARNING: Make sure the polarity and the PV panel voltage between the +
and the cable connectors of the PV panels are correct. Then connect the
panels to the DC terminal block on the power distribution board.
The PV panel open circuit voltage should be at or below the listed voltages in Figure 9
under all circumstances. Each DC input to the DC terminal block must be less than the
voltages listed in Figure 9.
StarInverter
Model
PV Panel Open Circuit
Voltage
DC Input to DC Terminal
Block
PVP3200 AND
2800-XV
500VDC 500VDC
PVP2900 500VDC 500VDC
PVP2000 450VDC 450VDC
Figure 9: PV open circuit voltages.
AC Ground
Line 2/
Neutral
Page view 10
1 2 ... 6 7 8 9 10 11 12 13 14 15 16 ... 22 23

Comments to this Manuals