Technical Data SMA Solar Technology AG
64 SB25_30-IA-IEN115050 Installation Manual
Protective Devices
General Data
Overvoltage category according to IEC 60664-1
III
Maximum cable length at conductor cross-section
of 1.5 mm²
9m
Maximum cable length at conductor cross-section
of 2.5 mm²
15.5 m
DC reverse polarity protection Short-circuit diode
Input-side disconnection device Electronic Solar Switch
DC overvoltage protection Thermally monitored varistors
AC short-circuit current capability Current control
Mains monitoring SMA Grid Guard 2.1
Maximum permissible fuse protection 16.0 A
Earth fault monitoring Insulation monitoring: R
iso
>1MΩ
Galvanic isolation Available
Width x height x depth with Electronic Solar Switch
440 mm x 339 mm x 214 mm
Weight 28 kg
Length x width x height of packaging 532 mm x 392 mm x 318 mm
Transport weight 33.1 kg
Climatic category according to IEC 60721-2-1 4K4H
Operating temperature range − 25°C … +60°C
Maximum permissible value for relative humidity,
non-condensing
100%
Maximum operating altitude above MSL 2 000 m
Noise emission (typical) 33 dB(A)
Power loss in night operation 0.25 W
Topology LF transformer
Cooling concept Convection
Electronics degree of protection according to
IEC 60529
IP65